MarkingWiki Presented by Columbia Marking ToolsMarkingWiki Presented by Columbia Marking Tools
  • Home
    •  Columbia Marking Tools
    •  I-Mark and Laser Website
  •  Technical References
    • Stamping Information
      • Marking Pressure Chart
      • Estimated Marking Force
    • Steel Stamp Information
      • Character Size
      • OCR-A Optical Character Recognition Font
    • 2D Code Explained
      • Direct Part Marking
      • 2D Terms & Definitions
      • 2D code Benefits
      • 2D Code Factors
      • 2D Code – Number of characters Encrypted
      • 2D Code Size
      • DOD UID Marking
      • 2D Code Marking Method Comparison
      • 2D Code – Patented Square-Dot®
      • 2D Code on Cast Surfaces
    • Air Impact Model Pressure Chart
      • Air Requirements
    • Press Marking
    • Roll Marking
    • Dot-Peen Marking
    • Scribe Marking
    • Laser Marking
  • Library
    • Library – Air Impact Markers
    • Library – Dot-Peen, Scribe and Laser Marking Catalogs
    • Library – Dot-Peen, Scribe and Laser Marking Technical Guides
    • Library – Hot Stamping
    • Technical Papers
    • Case Studies
    •  Submit Question

I-Mark Controller FAQ

Dot-Peen

Remote Technical Support

Columbia Marking Tools is expanding our service department and helping reduce customer service costs. In today’s changing environment, onsite service calls may be restricted or costly.

By Marc Steele, 6 yearsMarch 26, 2020 ago
Dot-Peen

I-Mark – Recovery after Safety Stop

Q: What is the recovery if the safety were to go down in the middle of the marking. This does not necessarily stop the marker but the air will go down causing the marker to not mark even though it completes the sequence. What would be your suggestion on how Read more

By Marc Steele, 6 yearsMarch 6, 2020 ago
Dot-Peen

I-Mark Application Fault (1)

Q: Our IM-IS60, has a fault, Application Fault (1): Layout Not Found. We were unable to find any information for this and was hoping you could give us some guidance. A: It means you’re trying to mark a layout number which is not assigned to the controller. There’s a button Read more

By Marc Steele, 6 yearsFebruary 17, 2020 ago
I-Mark

I-Mark Controller Serial Data Speed

Q: Can the serial data rate be changed from 115200?  We may need to run a serial connection longer distances and 115200 doesn’t support very long runs (maybe a couple of meters). A: Yes, this is configurable within the marking controller specifications. If you have further questions or would like Read more

By Marc Steele, 6 yearsDecember 6, 2019 ago
I-Mark

I-Mark Tag Map for Implicit Ethernet IP Communications

Q: Would you happen to have a Tag Map for implicit communication from a compact logix to an I Mark controller? A: Attached is an example project where you can find the mapping of the bits and their function. I-Mark-Ethernet-Example

By Marc Steele, 6 yearsAugust 23, 2019 ago
I-Mark

I-Mark EthernetIP Programming guide for RSLogix 500

Manual in PDF form to download

By Marc Steele, 7 yearsFebruary 1, 2019 ago
I-Mark

Q and A My I-Mark is printing backawards.

Problem: We took a controller from another machine that is undergoing some work. The controller I have currently has all the correct firmware.  I do have an issue, whenever I print out data, it seems to all be backwards.  IE, if I try to print 1234, I get 4321.  Do Read more

By Drew Davis, 10 yearsOctober 1, 2015 ago
I-Mark

Tech Support for marker with firmware updates.

Q: Hello,   I am trying to reach someone in the customer support group that might be able to help me with an error that I am seeing on our machine (SN AJ3832).  The error says that either the firmware on the controller stopped running or that the firmware does Read more

By Drew Davis, 11 years ago
I-Mark Controller FAQ

Configuring IP Address

Q When trying to connect my lap top to my marking machine I receive an error letting me one or more marking machines could not connect even though they are visible.   A: Your network setting on your controller and PC need to match in order to connect .   Configuring Read more

By Drew Davis, 11 yearsJanuary 13, 2015 ago
I-Mark

I-Mark Controller Start Signal

Q: I’m working with a I-Mark Series impact printer and need to know how long the I need to hold the cycle start ON for to get the marker started?   A: The I-Mark marking system only requires a momentary Start Signal to begin the marking sequence. As short at Read more

By Marc Steele, 13 years ago

Posts navigation

1 2 Next
Examples and Answers
  • Laser Marking
  • Dot-Peen
  • Scribe Marking
  • I-Mark
  • Roll Marking
  • Marking Press
  • Air Impact Markers
  • Numbering Head
  • Hot stamping
  • Hand tools
  • Marking Stamps and dies
  • Tooling and Fixtures
  • Misc
Complete Subject Listing
  • Columbia Marking Tools
  • Login
Hestia | Developed by ThemeIsle